GFRC Properties: Strength, Density, Frost Resistance

The properties of glass fibre reinforced concrete (GFRC) are described by several indicators: flexural and compressive strength, density, water absorption, frost resistance and combustibility. Flexural strength is what sets GFRC apart from ordinary concrete: it comes from alkali-resistant glass fibre, which is why element walls can be thin.

Specific values depend on the mix design, the forming method and the age of the samples, so manufacturers should be compared on test reports rather than advertising figures. According to TECHNOFORMA Group, its GFRC is non-combustible (class NG under the Russian classification) and has high frost resistance, further improved by admixtures.

This article is for designers, technical supervision and clients who need to know which figures to ask for. A general overview is in GFRC: material and technology.

Key performance figures

Below are indicative ranges typical for the industry. Values depend on the mix design and technology; exact data are in the product data sheet and the test report.

The indicators are interrelated. A dense matrix with a low water-cement ratio gives high compressive strength, low water absorption and good frost resistance at the same time. Fibre content and orientation have the greatest influence on flexural strength and on how the element behaves after the first crack. So when comparing manufacturers, look at a set of figures from one test report rather than a single favourable number.

IndicatorTypical rangeDepends on
Densityabout 1,900–2,200 kg/m³Composition, degree of compaction
Flexural strength (modulus of rupture)around 15–30 MPa for spray-up, lower for vibration castingFibre content and orientation, age
Compressive strengtharound 40–80 MPaCement, water-cement ratio
Water absorptiona few percent by weightMatrix density, admixtures
Frost resistancehigh; the exact grade is set by testingMix design, admixtures, water absorption
CombustibilityNG (non-combustible), according to the companyMineral composition
Wall thicknessusually 10–20 mmForming method, element size

Four groups of factors have the strongest effect on the final properties: the mix design (cement grade and content, water-cement ratio, polymer admixtures, sand fraction), fibre content and length, the forming method and the curing conditions — the moisture regime during the first day, when the matrix gains strength and bond with the fibre develops. An element that dries out in the first hours can have noticeably lower flexural strength than properly cured samples of the same mix.

Forming methodReinforcementTypical property featuresWhere used
Spray-upchopped fibre oriented in the plane of the layer, higher contenthighest flexural strength; thin wall; quality depends on operator skill and thickness controllarge panels, column casings, large-section cornices
Vibration casting (premix)fibre mixed into the batch, random orientation, lower contentlower flexural strength than spray-up; stable geometry and good reproduction of fine reliefsmall and medium ornament, capitals, brackets, balusters
Combinedface coat without fibre or with little fibre, then a reinforced backing layerclean face with no protruding fibres; properties governed by the reinforced layerelements with demanding surface texture requirements

The assessments in the table are general and comparative; only a test report gives specific figures for each method and mix design.

Flexural and compressive strength

GFRC strength is described by two groups of indicators. Compressive strength is governed by the cement matrix and is close to that of high-grade fine-grained concretes. For cladding it is rarely critical: a panel carries no vertical load from the building.

Flexural strength is the key figure for facade elements. A panel is subject to wind load, its own weight between fixing points and thermal movement. For GFRC two values are distinguished: the limit of proportionality (the stress up to which the material behaves elastically, without cracks) and the modulus of rupture (the failure stress). The latter is provided by the fibres, which hold the crack together and prevent brittle failure.

Age also matters: GFRC flexural strength can decrease over the years, so calculations use long-term values with safety factors rather than initial ones. This is addressed by alkali-resistant fibre, admixtures and a correct mix design.

How flexural strength is measured. Strip specimens are cut from a control board formed together with the production batch by the same method and tested in bending, usually in a four-point arrangement. The load–deflection curve gives the limit of proportionality (first crack) and the modulus of rupture. For sprayed material, specimens are tested in two directions and loaded on both the face and the back side, because fibre orientation and variation through the thickness make a difference.

What this means for a project:

• wall thickness and stiffening ribs are selected by calculation from long-term flexural strength and the wind load for the specific location and height;

• fixing spacing and panel size are linked: the longer the span between supports, the higher the bending stresses;

• working stresses are kept below the limit of proportionality so that no cracks appear in service; the margin up to the modulus of rupture is a reserve for overloads;

• large flat panels are often stiffened with a steel frame on flexible anchors that do not restrain thermal and moisture movement of the skin.

Flexural test of a GFRC specimen in a laboratory
Flexural test of a GFRC specimen in a laboratory

Frost resistance and water absorption

The frost resistance of GFRC is its ability to withstand repeated freezing and thawing when saturated with water without losing strength or surface damage. It is directly linked to water absorption: the denser the matrix and the fewer open pores, the less water enters the material and the lower the internal ice pressure.

According to TECHNOFORMA Group, its GFRC has high frost resistance, improved with admixtures. In practice resistance is increased by:

• a low water-cement ratio and plasticisers;

• polymer and air-entraining admixtures;

• water-repellent treatment of the face;

• correct details that prevent water standing on horizontal elements (drips, falls on cornices).

Trade names of admixtures and products for winter concreting that turn up in search results have nothing to do with the frost resistance of a finished element: a frost resistance grade is confirmed only by testing specimens.

Besides frost resistance, durability is affected by shrinkage and moisture movement: the cement matrix changes size as it dries and gets wet, and in thin-walled elements this is more noticeable than in mass concrete. If a panel is rigidly restrained around its perimeter, this movement creates stresses and cracks. So fixings are designed with sliding supports, and panel sizes and joint widths allow for movement.

Typical mistakes that make a material frost-resistant on paper fail on the facade:

• horizontal surfaces without falls, where water stands and freezes;

• no drip grooves on projecting elements, so water runs onto the soffit and the back face;

• open cavities and ends where snow packs in;

• joint sealant not designed for the movement, so water gets behind the cladding through tears;

• de-icing salts at plinths and steps; for these zones frost resistance is tested in a salt solution, not only in water.

Fire performance

GFRC consists of mineral components — cement, sand, glass fibre and water — so according to the company it belongs to combustibility class NG (non-combustible). This is an important difference from polyurethane, polymer and expanded polystyrene mouldings.

For multi-storey residential buildings, public buildings and hotels, requirements for the combustibility of cladding and rainscreen systems are set by the applicable fire safety codes (in Russia, sets of rules SP). Non-combustible cladding makes these requirements easier to meet, but the fire safety of the facade as a whole is determined by the entire system: insulation, substructure, wind barrier and fire breaks. So the system must be assessed, not just the panels.

When heated, GFRC does not melt, produce burning droplets or support combustion. Under prolonged high-temperature exposure, like any cementitious material, it gradually loses strength and the surface may crack. For facades this means that GFRC elements do not spread fire across the cladding, but their fixings and substructure must also meet the design requirements.

How to verify declared properties

Declared properties are a promise; documents and tests confirm them. What to request from the manufacturer:

1. Test reports for flexural and compressive strength, density, water absorption and frost resistance, with the date, laboratory and specimen description.

2. A product data sheet or the technical specifications the products are made to.

3. Fibre documentation confirming alkali resistance.

4. Combustibility data for the material.

5. Control specimens from your batch, which can be tested in an independent laboratory.

The same approach works for any facade material. The properties of shell limestone (coquina) blocks or travertine depend on the deposit and the specific batch: density, strength and water absorption can differ markedly between two quarries of the same stone. Insulation properties (for example, mineral wool facade boards) are taken from the manufacturer's technical documentation for the specific product. In every case compare figures in documents, not in advertising.

Which properties matter for which elements is easy to check in the table, so you request exactly what affects your project.

Element or zoneCritical indicatorsWhat to watch
Large facade panels at heightflexural strength (long-term), densitywind calculation, sliding fixing layout
Cornices, window pediments, string coursesfrost resistance, water absorptionfalls, drip grooves, protection of top surfaces
Plinths, steps, parapets by pavementsfrost resistance in salt, impact resistancede-icing salts, mechanical damage
Cladding of multi-storey and public buildingscombustibility, strengthrequirements for the rainscreen system as a whole
Column casings, curved elementsflexural strength, dimensional stabilityforming method, wall thickness

Typical mistakes when comparing offers: comparing flexural strength of specimens of different ages; setting spray-up figures from one supplier against cast figures from another; accepting data for "the material in general" instead of reports on the products that will go to site; not checking that specimens were made by the same method as the elements. If a report does not state the forming method, specimen age and curing conditions, it is almost useless for comparison.

GFRC control specimens for frost resistance testing
GFRC control specimens for frost resistance testing

Examples from TECHNOFORMA projects

At RUBLEVO BUSINESS PARK in Moscow the company carried out facade design and installation: 15,000 m² of GFRC and 5,000 m² of FRONTEK on two 12-storey buildings. For an office centre in Moscow, both wind loads at height and freeze–thaw cycles in the shoulder seasons matter.

At Triumph residential complex in Makhachkala — 11,500 m² of GFRC, completed in 2021. More projects are in TECHNOFORMA projects. How density turns into load on the facade is covered in How much GFRC weighs and how it affects facade loads.

FAQ

What is the density of GFRC in kg/m³?

Usually about 1,900–2,200 kg/m³, depending on composition and degree of compaction. The exact value is stated in the test report for the specific mix design.

How strong is GFRC?

Flexural strength of sprayed GFRC is roughly 15–30 MPa, compressive strength 40–80 MPa. Values depend on the mix design, forming method and specimen age.

How frost-resistant is GFRC?

Highly: a dense matrix with low water absorption tolerates freeze–thaw cycles well. The specific frost resistance grade is confirmed by testing specimens.

Does GFRC burn?

No. According to TECHNOFORMA Group, its GFRC belongs to combustibility class NG — non-combustible.

How do I check a manufacturer's GFRC properties?

Request specimen test reports, the product data sheet and documents for the alkali-resistant fibre, and if necessary test control specimens from your batch in an independent laboratory.

How do the properties of sprayed and cast GFRC differ?

Spray-up gives a higher fibre content oriented in the plane of the element, so flexural strength is usually higher. Casting (premix) is better for fine relief and stable geometry, but its flexural strength is generally lower. Exact values depend on the mix design and are given in the test report.

Related articles

All articles
What Is GFRC and Where Is It Used

GFRC: material and technology

What Is GFRC and Where Is It Used

Glass fibre reinforced concrete (GFRC) is a fine-grained concrete reinforced throughout its volume with alkali-resistant glass fibre. The fibre takes the tensile stresses, so GFRC can be used to make thin-walled, lightweight elements of complex shape: facade panels, cornices, columns, window surrounds, decoration and small architectural forms.The main selection criterion is not the material itself but the quality of production: the mix design, the fibre type, the forming method and control at every stage. These determine strength, frost resistance and the geometry of the elements.The material is chosen by architects and developers who want an expressive facade without heavy stone or cast-in-place concrete, and by private homeowners who want classical decoration that can stand up to the weather. More about the material in GFRC: material and technology.

GFRC Composition: Cement, Sand and Alkali-Resistant Fibre

GFRC: material and technology

GFRC Composition: Cement, Sand and Alkali-Resistant Fibre

Glass fibre reinforced concrete (GFRC) consists of four basic components: cement, fine sand, alkali-resistant glass fibre and water. Plasticisers and modifying admixtures are added to control the workability of the mix, the rate of strength gain and frost resistance.The key component is the fibre: it must be alkali-resistant, otherwise the cement environment gradually destroys it and the element loses flexural strength. So when choosing a supplier, the question is not just what goes into the mix, but which materials the manufacturer actually uses, in what proportions, and how it controls them.This article is for architects, technical supervision engineers and clients comparing offers from GFRC manufacturers. For a general overview of the material, see GFRC: material and technology.

GFRC Production Technology: Spray-Up and Vibration Casting

GFRC: material and technology

GFRC Production Technology: Spray-Up and Vibration Casting

Glass fibre reinforced concrete (GFRC) production comes down to two main forming methods: spray-up, in which the mortar and chopped glass fibre are sprayed into the mould simultaneously, and vibration casting, in which a ready mix containing fibre is poured into the mould and compacted by vibration. These are followed by curing, demoulding, surface finishing and quality control.The method is chosen to suit the element: spray-up for large thin-walled panels with high flexural strength requirements, vibration casting for three-dimensional decoration and small, intricate elements. The result depends on production discipline as much as on the method.This article is for designers and clients who want to understand what happens at the plant and what to check. A general overview is in GFRC: material and technology.

How Much GFRC Weighs and How It Affects Facade Loads

GFRC: material and technology

How Much GFRC Weighs and How It Affects Facade Loads

The weight of glass fibre reinforced concrete (GFRC) is determined by the density of the material (roughly 1,900–2,200 kg/m³) and the wall thickness. At the 10–15 mm thickness typical for facade panels, a square metre of GFRC weighs about 20–35 kg, excluding ribs, frame and embedded items. That is several times lighter than natural stone or precast concrete cladding of the same area.The key thing for the designer is to calculate not a notional weight per square metre but the actual weight of each element with stiffening ribs, frame and fixings: this is what determines bracket spacing, substructure sections and the load capacity of the anchors in the wall.This article is for ventilated facade designers, technical supervision and clients comparing cladding options. A general overview is in GFRC: material and technology.

Request a callback