Facade Energy Efficiency and Building Heat Loss

Facade energy efficiency is the ability of external walls to retain heat in winter and not overheat in summer with minimal energy spent on heating and cooling. It is determined by the reduced thermal resistance of the wall: the thickness and quality of insulation, the number of thermally conductive elements and the airtightness of the construction.

The main criterion when choosing a solution is not maximum insulation thickness but the absence of weak spots: thermal bridges, gaps in the insulation, draughty details. A well-designed ventilated rainscreen facade with continuous insulation and thermal breaks in the fixings noticeably reduces heat loss through the walls.

The article is written for developers, designers, owners and property managers. Related topics: Facade maintenance, standards and repair.

Heat loss

A building's heat loss is distributed between several paths: through walls, windows, the roof, the floor above the basement or on the ground, and with ventilation and air infiltration. The share of each path depends on the architecture, glazed area, number of storeys and condition of the structures. In multi-storey buildings walls are one of the major sources of loss, so a building's thermal protection is unthinkable without a good facade.

Heat loss through walls depends on:

• thermal resistance — the higher it is, the lower the heat flow for the same temperature difference;

• wall area and the difference between indoor and outdoor temperatures;

• thermally conductive elements — brackets, floor slabs extending to the facade, balcony slabs, reveals;

• moisture in the insulation — wet insulation conducts heat much better than dry;

• air permeability — wind passing through fibrous insulation without a wind barrier carries heat away.

Actual wall losses are almost always higher than those calculated for the plain wall area, so the codes require the reduced thermal resistance to be used, adjusted for non-uniformities.

Standards

Thermal protection requirements are set by the Russian code SP 50.13330 "Thermal performance of buildings". The logic of the code:

• Element requirements — the required thermal resistance of walls, windows and roofs. It depends on the heating degree-days (the climate of the area) and the building's use: requirements for Moscow are higher than for southern regions.

• Overall requirement — the specific thermal performance characteristic of the building as a whole.

• Sanitary requirement — the internal wall surface temperature must not drop below the dew point, otherwise condensation and mould appear.

• Protection from excess moisture — moisture must not accumulate in the construction from year to year.

In addition, Federal Law No. 261-FZ "On energy saving" and related requirements define energy efficiency classes for buildings. For new construction and major repairs, compliance is confirmed by an energy passport as part of the design.

Installing mineral wool insulation on a rainscreen facade
Installing mineral wool insulation on a rainscreen facade

Insulation

The main way to improve wall thermal protection is external insulation. Placing insulation on the outside is better than on the inside: the wall stays in the warm zone, the dew point moves into the insulation, and floor slabs do not become thermal bridges.

SystemInsulationFeatures
Ventilated rainscreen facadeMineral wool boards, often with a wind barrierThe ventilated cavity removes moisture, cladding of any weight and texture, easy to repair
Rendered facade (ETICS)Mineral wool or expanded polystyreneCheaper, but limitations on cladding and fire safety
Three-layer masonryInsulation within the wallRepairing the insulation is practically impossible

In a rainscreen facade the insulation is fixed with disc-head plugs, boards are laid staggered, without gaps and tight to the brackets. The thickness is determined by a thermal calculation to SP 50.13330 for the specific region. For taller buildings non-combustible insulation is used in line with fire safety requirements.

Thermal bridges

Thermal bridges are areas through which heat escapes faster than through the main wall area. In facades these are:

• metal substructure brackets passing through the insulation;

• edges of floor slabs and balcony slabs reaching the facade;

• window reveals and frame junctions;

• gaps in the insulation, loose joints between boards;

• metal anchors and plugs.

At thermal bridges not only does heat loss increase, but the internal surface temperature also falls — condensation and mould appear in corners and at reveals. Remedies: thermal break pads under brackets, brackets made of less conductive materials, optimising the number of fixing points, insulating reveals and slab edges, balcony connections with thermal breaks. A detailed analysis is in a separate article on thermal bridges in rainscreen facades.

The effect of thermal bridges is easy to underestimate: with many brackets without thermal breaks and uninsulated reveals, the actual reduced thermal resistance of the wall can be noticeably lower than that calculated for the main area. That is why rainscreen systems are compared not only by insulation thickness but also by the specific heat losses through fixing points, which are given in the system's technical documentation.

Economics

The economic effect of facade insulation has several components:

• Lower heating costs — in proportion to the reduction of heat loss through the walls; depends on the climate, tariffs and the initial condition of the building.

• Lower load on building services — in new construction, smaller heating and cooling capacity can be designed.

• Durability — a wall in the warm zone is less exposed to freeze–thaw cycles.

• Comfort and no mould — fewer complaints from residents and tenants, higher attractiveness of the property.

• Energy efficiency class — for the developer, it affects compliance and marketing.

The payback period of insulation varies greatly by region and building, so it is calculated for the specific building: calculated heat losses before and after, the cost of heat and the cost of works are compared. In reconstruction it usually pays to combine insulation with replacing the cladding — scaffolding, access and removal costs are incurred only once.

Diagram of building heat loss through the envelope
Diagram of building heat loss through the envelope

Examples from TECHNOFORMA projects

TECHNOFORMA Group carries out insulation, installation of rainscreen substructures and cladding in GFRC, stone and porcelain stoneware with its own installation team. Examples of facades:

• RUBLEVO BUSINESS PARK business centre in Moscow — 2 buildings, 15,000 m² of GFRC and 5,000 m² of FRONTEK; design and installation.

• Al-Qasr hotel complex in Dagestan — 4 buildings, 24,000 m² of GFRC.

All projects are under TECHNOFORMA projects. How to find and eliminate weak spots in thermal protection is covered in Thermal bridges in ventilated facades.

FAQ

How can heat loss through walls be reduced?

Install external insulation of the calculated thickness, eliminate thermal bridges with thermal breaks and insulated reveals, and protect the insulation from wind-washing and wetting.

What insulation thickness does a facade need?

It is determined by a thermal calculation to the Russian code SP 50.13330 for the specific region and building use, taking into account the thermally conductive elements of the substructure.

What does a ventilated facade do for energy efficiency?

It provides a continuous insulation layer on the outside of the wall, removes moisture through the ventilated cavity and allows thermal bridges to be eliminated with thermal breaks. The insulation stays dry and keeps its properties.

Does facade insulation pay for itself?

The payback period depends on climate, tariffs and the initial condition of the building; it is calculated individually. It is most cost-effective to combine insulation with replacing the cladding.

Which standards define a building's thermal protection?

The Russian code SP 50.13330 "Thermal performance of buildings" and energy saving legislation, including energy efficiency classes.

Related articles

All articles
GFRC Care and Maintenance

Facade maintenance, standards and repair

GFRC Care and Maintenance

Caring for glass fibre reinforced concrete (GFRC) comes down to three regular tasks: inspection, gentle cleaning and periodic renewal of the protective impregnation. GFRC is a fine-grained concrete reinforced with alkali-resistant glass fibre; it does not rot or corrode and is classed as non-combustible, so it needs no special care of the kind timber or metal require.The durability of GFRC decoration and panels depends above all on the condition of the surface layer and the fixing points. If the surface is protected from water saturation and the joints and cast-in anchors are sound, the elements keep their shape and colour for years. The material is chosen by developers and managers of apartment buildings, owners of private houses with facade decoration, and maintenance teams of public buildings.Below is the maintenance procedure from a GFRC manufacturer. More articles in this section: Facade maintenance, standards and repair.

Repairing Chips and Cracks in GFRC

Facade maintenance, standards and repair

Repairing Chips and Cracks in GFRC

Repairing glass fibre reinforced concrete (GFRC) means restoring an element in place: filling chips, blowholes and cracks with repair compounds compatible with GFRC in strength, deformability and colour. It is justified when the defect is local and does not affect the fixing or the load-bearing capacity of the element; otherwise the element is replaced.The main criterion for choosing between repair and replacement is the cause of the damage. A chip from a scaffold impact can be closed in an hour, whereas a crack caused by a misaligned substructure will reappear after repair unless the fixing itself is corrected. That is why every repair starts with an assessment.The article is written for maintenance teams, technical supervision and general contractors who accept or maintain facades with GFRC decoration. Related topics: Facade maintenance, standards and repair.

Facade Cracks: Causes and What to Do

Facade maintenance, standards and repair

Facade Cracks: Causes and What to Do

Cracks on a facade are a sign that stresses in the wall or cladding have exceeded the strength of the material. The causes vary: render shrinkage, thermal movement, corrosion of fixings, foundation settlement. Some cracks are cosmetic, others signal a structural problem, and they can only be told apart by their pattern, location and development over time.The main rule is to find the cause first and repair second. A crack from settlement or a distorted substructure that is filled without a survey will open again, and it can sometimes mask a dangerous condition of cladding above a pavement.This guide is useful for building owners and management companies, technical supervisors and maintenance services. Other articles are in the Facade maintenance, regulations and repair section.

Thermal Bridges in Ventilated Facades

Facade maintenance, standards and repair

Thermal Bridges in Ventilated Facades

Thermal bridges in a facade are areas of the building envelope through which heat escapes faster than through the rest of the wall. In a ventilated rainscreen facade the main thermal bridges are the metal substructure brackets, which pass through the insulation layer and connect the cold cladding to the warm wall.The key to a correct solution is to reduce heat flow at fixing points and keep the insulation continuous. To do this, thermal break pads are placed under the brackets, the number of fixing points is optimised, and reveals and junctions are carefully insulated.This article is for designers, technical supervision, installation contractors and clients of rainscreen facades. Related topics are in Facade operation, codes and repair.

Request a callback