Facades in Seismic Zones: Fixing the Cladding

A facade in a seismic zone is designed so that in an earthquake the cladding does not tear away from the building and fall on people. To achieve this, the cladding weight is reduced, fixings and substructure are calculated for seismic loads, gaps are left so that elements can move with the frame, and the building's movement joints are repeated in the cladding.

The main criterion is the reliability of the mechanical fixing of every element at the design seismicity of the site. Lightweight materials such as glass fibre reinforced concrete (GFRC) make the task easier, but any cladding needs calculation.

This article is for architects, structural engineers and developers working in the North Caucasus, Crimea, the Far East, Siberia and other areas of high seismicity. Other design issues are covered in Facade design and selection.

Loads

In an earthquake, a facade is subjected to loads that do not occur in normal conditions:

LoadNatureHow the risk is reduced
InertialThe cladding tends to stay in place while the building moves; the force is proportional to the element's massLight cladding, reliable fixings
Inter-storey driftFloors shift relative to each other and the wall deformsMovable fixings, gaps between elements
Vertical componentUp-and-down shocks, especially dangerous for cantilevered decorFixings designed for pull-out, secondary safety fixings
PoundingNeighbouring elements strike each other as they moveSufficient joint width

The inertial load on an element is greater the heavier it is and the higher it sits on the building: upper floors oscillate with greater amplitude. So large cornices and parapet decor at the top of a tall building are the most critical details.

Seismic loads are added to the usual ones: dead load, wind and thermal movement. The calculation is made for their combination.

As a guide, site seismicity is expressed in points on the MSK-64 scale, and seismic design is mandatory for sites with a design seismicity of 7 points and above. In Dagestan, Chechnya, Ingushetia, Kabardino-Balkaria and other North Caucasus republics, a large part of the territory falls into areas of seismicity 7–9 points, so seismic calculation is a standard part of facade design there.

Requirements

The main code for design in seismic areas of Russia is the Russian standard SP 14.13330 'Construction in seismic areas'. Site seismicity is determined from the general seismic zoning maps and refined by site investigations. Requirements for facade systems follow from the general provisions of the code and from the suitability documents of the particular system.

In practice this means:

• the rainscreen substructure must be approved for use in seismic areas and calculated for the specific site;

• cladding elements are fixed mechanically; adhesive-only fixing of heavy cladding at height is not permitted;

• anchors in the substrate are pull-out tested and their capacity is confirmed;

• decor and attached elements are calculated for seismic action together with their fixings;

• the cladding must not bridge the building's movement and seismic joints.

Specific coefficient values and requirements for details are determined by the designer according to current codes and the substructure manufacturer's documents.

GFRC decor fixing detail with cast-in fixings
GFRC decor fixing detail with cast-in fixings

Fixing Methods

The cladding fixing method in a seismic zone is chosen according to the element's mass and size and the substrate:

• Slabs on a rainscreen substructure (porcelain stoneware, stone, GFRC panels) are fixed with clips or concealed fixings to rails; the substructure has movable connections that accommodate displacement.

• GFRC decor such as cornices, window surrounds and pilasters is fixed through cast-in fixings embedded in the element to the substructure or to the load-bearing structure. Thin-walled GFRC elements are much lighter than stone ones, which reduces the inertial load.

• Thick natural stone is fixed with anchors, dowels and brackets of corrosion-resistant steel; adhesive may be used only as an additional measure.

• Cantilevered decor (cornices with a large projection, balcony elements) is backed up by secondary safety fixings.

Fixings are designed together with the elements: the position, number and type of cast-in fixings depend on the element's shape. It is therefore more convenient when one organisation develops both the elements and the details. At TECHNOFORMA Group, the design department produces working documentation for the substructure and cladding, and the elements are made at the company's own production facility.

Comparison of cladding for a seismic zone by weight and fixing:

CladdingWeightFixingNotes
Porcelain stoneware on a rainscreenLowClips, concealed fixingBrittle under impact; needs gaps and pads
GFRC panels and decorMedium, thin-walled elementsCast-in fixings, brackets, substructureLarge elements at moderate weight
Natural stoneHighStainless steel anchors, dowels, bracketsThe highest inertial loads
Adhesive-fixed tiles, renderLowAdhesive on the substrateCracks under wall drift, risk of detachment

Movement Joints

The building's movement joints (thermal, settlement and seismic) divide the frame into independent blocks. In an earthquake the blocks move relative to each other, and if the cladding runs continuously across a joint, it will be destroyed.

• The cladding and substructure are broken on the axis of every building movement joint.

• The joint is closed with a compensating element that allows movement: a flexible profile or a cover strip fixed on one side.

• Decor such as cornices and string courses is divided into separate elements at the joint.

• Gaps are left between cladding elements, with a width set by calculation; they must not be filled with rigid mortar.

Architecturally, it is convenient to combine a movement joint with a compositional division: a pilaster, a change of material, the corner of a projecting bay. Then it does not read as a defect.

Junctions between cladding and windows or curtain walls need particular attention. Window units and cladding are fixed to different structures and move differently during oscillations. The junction is designed with a gap and an elastic seal so that a GFRC or stone window surround does not press on the frame or spall when the opening racks.

The width of joints between slabs on the substructure is also set with the design storey drift in mind.

Documents

For a facade in a seismic zone, the client and technical supervision need:

1. a suitability document for the facade system (technical certificate or equivalent) stating that it may be used in seismic areas;

2. a calculation of the substructure and fixings for the combination of loads, including seismic, for the specific site;

3. working documentation: substructure shop drawings, cladding layout, fixing and movement joint details;

4. pull-out test reports for anchors in the substrate;

5. data sheets and test reports for cladding elements;

6. as-built documentation: records of concealed work on anchoring and substructure, as-built drawings.

These documents will be needed both for design review and for acceptance of the facade.

Typical mistakes found when inspecting facades in seismic zones: heavy elements fixed only with adhesive; cladding bridging a movement joint; anchors in hollow blocks or weak brick without testing; rigid mortar in joints; cantilevered decor without safety fixings; a substructure not approved for seismic areas. After an earthquake the facade is inspected: fixings, cracks in elements and displacement of elements are checked, and damaged details are restored before the next season.

Movement joint in rainscreen facade cladding
Movement joint in rainscreen facade cladding

Examples from TECHNOFORMA Projects

TECHNOFORMA Group's projects are located mainly in the seismically active areas of the North Caucasus. The Dominanta residential complex in Makhachkala: 4 buildings of 18 storeys, 14,000 m² of GFRC and 13,000 m² of porcelain stoneware, design and installation, 11.2022–10.2024.

The Anzhi-City residential complex in Makhachkala: 16 storeys, 18,000 m² of GFRC cladding, design and installation, 09.2022–12.2024. Other projects are in the TECHNOFORMA projects section. How details and decor are coordinated in the building model is explained in BIM and 3D modelling of facades.

FAQ

How is a rainscreen facade made earthquake-resistant?

Use a substructure approved for seismic areas, calculate it and its fixings for seismic action, fix the cladding mechanically and leave gaps and movement joints.

Which cladding is best for a seismic zone?

Light cladding with reliable mechanical fixing: GFRC panels and decor, porcelain stoneware on a substructure; heavy stone with reinforced fixing according to calculation.

Can stone be bonded to a facade in a seismic zone?

Heavy cladding at height must not be bonded without mechanical fixing; adhesive is acceptable only as an additional measure.

Which code governs construction in seismic areas?

The Russian standard SP 14.13330 'Construction in seismic areas', and for the facade system, its suitability documents and calculation.

What happens to the cladding at a building movement joint?

The cladding and substructure are broken on the joint axis and the joint is closed with a compensating element.

Should a facade be inspected after an earthquake?

Yes. After noticeable tremors, the fixings of cladding and decor, cracks in elements, displacement of elements and the condition of joints are checked. Damaged details are restored, and elements with failed fixings are temporarily fenced off or removed.

Related articles

All articles
How to Choose Facade Cladding: Criteria and Comparison

Facade design and selection

How to Choose Facade Cladding: Criteria and Comparison

How to choose facade cladding: start not with the material but with the conditions: building type and height, load-bearing capacity of the walls, climate, fire safety requirements, local planning regulations, budget and service life. Only then compare materials: natural stone, glass fibre reinforced concrete (GFRC), porcelain stoneware, fibre cement and composite panels, clinker, render and metal cassettes.For multi-storey buildings the main criterion is the system as a whole: cladding, substructure, insulation and fixings must be compatible and permitted for a building of that height and fire hazard class. An attractive slab on an unsuitable substructure is a risk, not a saving.This article is for architects, developers, general contractors and private homeowners. TECHNOFORMA designs, manufactures and installs facades in GFRC, natural stone and porcelain stoneware, so the comparison below is a practitioner's view rather than that of a single-material seller. More on choosing a facade is in Facade design and selection.

Facade Design: Stages and Documents

Facade design and selection

Facade Design: Stages and Documents

Facade design is the development of a set of solutions and documents from which the facade will be manufactured and installed: from the architectural concept and choice of materials to working drawings of the substructure, cladding layout, details and specifications. For a ventilated rainscreen facade the design also includes calculations: wind load, cladding weight, anchor capacity, thermal performance.The main criterion of a good design is that it can be built without improvisation on the scaffold. If junctions, reveals and parapets are not detailed, installers resolve them on site, and that is exactly where leaks, cracks and efflorescence later appear.This article is for developers, general contractors, client-side technical managers and architects planning the schedule and budget of facade works. At TECHNOFORMA the design department consists of 12 designers led by two architects, as well as 3D visualisers; the design is developed together with manufacturing and installation. More on selection and design is in the section Facade design and selection.

Facade Architectural Concept: Where a Project Begins

Facade design and selection

Facade Architectural Concept: Where a Project Begins

A facade architectural concept is the first stage of a project, at which the image of the building is defined: composition, divisions, proportions, materials, colour and key details. The concept is presented as sketches, elevations and 3D visualisations; the client makes a decision on it, and designers then develop the working drawings.The main test of a good concept is that it can be built. An attractive image that cannot be manufactured in the required quantities, installed on the given wall or approved in the given city will have to be reworked, and the client loses time. So the concept should take materials, production technology and budget into account from the start.A concept is needed by developers of residential complexes and business centres, building owners refurbishing a facade, and architects who need the cladding worked out. At TECHNOFORMA concepts are prepared by the design department: 12 designers led by two architects, plus 3D visualisers. More on choosing and designing facades is in Facade design and selection.

BIM and 3D Modelling of Facades

Facade design and selection

BIM and 3D Modelling of Facades

A facade BIM model is a three-dimensional information model in which every cladding, substructure and decorative element exists as an object with dimensions, material, fixing and a product mark. Drawings, specifications and element schedules are generated from it, and clashes with other parts of the design are checked in it.The main benefit for a facade is not a nice picture but accuracy: decorative elements, cornices and window surrounds are coordinated with the architecture, structure and windows before production, and the product schedule is generated from the model automatically. For facades with complex glass fibre reinforced concrete (GFRC) and stone decoration this is especially important: each product is made to size.This article is for architects, BIM managers and developers. Other design questions are covered in the section Facade Design and Selection.

Request a callback